TK FieldWorks sample site Return to portfolio
Latchline Home Performance
  1. Home
  2. Services
  3. Air Sealing & Draft Control

Service 02

Stop treating every cold spot as an insulation problem.

Latchline investigates accessible air-leakage paths and completes targeted draft-control work around attics, hatches, service penetrations, rim joists and other appropriate building-envelope locations.

Six distinctions

Most draft conversations go wrong in the first sentence.

These six distinctions decide what should be done in your house. They are worth reading even if you never call us.

Air leakage vs. conductive heat loss

Heat riding on moving air is a different mechanism from heat conducting through a solid material. Sealing addresses the first. Insulation addresses the second. Neither substitutes for the other.

A cold surface vs. a moving draft

Standing beside a large cold window feels like a draft because your body is radiating heat toward it. No air is moving. Caulking will not change it; a thermal improvement or a curtain might.

Indoor air leaking out vs. outdoor air coming in

Both happen at once, at different heights. Sealing only where you feel cold air entering can leave the driver of the whole system untouched at the top of the house.

DIY caulking vs. systematic air sealing

A tube of caulk at a visible gap is worth doing and occasionally helps. Systematic sealing means finding the largest openings first, most of which are not visible from a living space.

Comfort improvement vs. guaranteed savings

Comfort changes are usually noticed. Dollar savings depend on weather, prices, behaviour and equipment. We will describe both, and only one of them comes with a number attached.

Contractor diagnostics vs. an EnerGuide evaluation

Our observations inform a scope of work. An official evaluation is conducted by a registered energy advisor and serves a different purpose. Latchline does not perform them and does not describe its work as one.

Where the air actually goes

A leakage map for the house type we see most often. Two of these six paths are invisible from inside the house and are almost never on a homeowner's list.

Leakage map of a Toronto semidetached house An elevation and section of a semidetached house with six numbered leakage points marked: the attic hatch, the party-wall transition at the roofline, the plumbing stack, the junction where a rear addition meets the original structure, basement service penetrations, and the rim joist around the foundation perimeter. ATTACHED NEIGHBOUR ADDITION BASEMENT 1 2 3 4 5 6 1  Attic hatch 2  Party-wall transition 3  Plumbing stack 4  Addition junction 5  Basement penetrations 6  Rim joist COMMON PATHS
Figure 01Six paths that show up repeatedly in Toronto semidetached houses. Points 2 and 4 are the ones homeowners rarely suspect: the shared wall at the roofline, and the seam where a rear addition was built against the original structure decades later.

High in the house

  • Attic hatch
  • Plumbing stacks
  • Electrical penetrations
  • Bath-fan housings
  • Dropped ceilings and bulkheads
  • Top plates of interior walls

Low in the house

  • Rim joists around the perimeter
  • Basement service penetrations
  • Around basement windows and hatchways
  • Where the foundation meets the framing

The seams nobody expects

  • Older window and door interfaces
  • Party-wall transitions in semis and rows
  • Additions meeting the original structure
  • Anywhere two construction eras meet
How we look

The tools, and what each one can honestly tell you.

Visual inspection

Still the highest-value tool. Someone who knows how a 1920s semi was assembled can predict where the openings are before finding them.

Infrared imaging, when conditions suit

Needs a real indoor-to-outdoor temperature difference. Shows surface temperature, not air movement. Excellent for locating missing insulation and thermal bridges; suggestive rather than conclusive about leaks.

Smoke pencil or controlled diagnostic smoke

Shows air actually moving, at a specific point, in real time. Unglamorous and very informative.

Moisture meter

Used wherever a leakage path and a moisture question overlap, which is more often than people assume.

Temperature comparison

Simple surface and air readings between rooms and heights. Establishes whether a complaint is about air movement or a cold surface.

Third-party testing when it is warranted

Blower-door or EnerGuide testing arranged through the appropriate people. We will tell you when a project genuinely benefits from a measured number rather than an informed observation.

Everything found is photographed and described. The output of an air-sealing assessment is not a verdict, it is a documented list of paths with an opinion about which ones are worth closing and in what order.

Safety

Tightening a house changes how it breathes.

This is the part of air sealing that deserves more attention than it usually gets.

Older houses have historically got their air exchange by accident, through the same leaks that make them uncomfortable. Reduce the leakage and you reduce the accidental ventilation along with it. For most Toronto houses receiving targeted sealing, the change is modest and the house remains well above the point where this is a concern. But the direction is worth naming out loud.

Two questions follow from it. First, is there adequate ventilation for the people living there — mechanical if the house is tight enough to need it. Second, and more urgently, does the house contain naturally aspirated combustion equipment: an atmospherically vented furnace, boiler or water heater that draws combustion air from the room and relies on a chimney to carry exhaust away.

Where a scope could plausibly affect either, we say so in writing, recommend a qualified inspection, and stage the work accordingly. We do not seal aggressively around combustion equipment and leave you to find out how it went.

Working carbon monoxide alarms are worth having regardless of whether anyone is doing work on your house.

Jonas sealing around a plumbing stack where it passes through the attic floor
Sealing at a plumbing stack. Once insulation is down, this is unreachable.
Dev using a thermal camera on a living room ceiling while the homeowner watches
Thermal imaging on a cold day, interpreted alongside smoke and physical inspection.
FAQ

Air-sealing questions homeowners ask

Find out where the air is going.

A draft investigation is the appointment for a house where the discomfort moves around and nobody can say why. The Scope Planner will tell you if that sounds like yours.